Free
Shipping
The Genuine Brivis Ducted Gas Heater Electronic Control Interface 509 (Part # 17529) is a critical component for Brivis ducted gas heaters. This electronic control interface is responsible for managing the operation of the heater, including ignition, temperature regulation, and safety functions. It ensures the heater operates efficiently and safely.
Part Number: 17529
Model: Electronic Control Interface 509
Function: Controls ignition, temperature regulation, and safety features in Brivis ducted gas heaters.
Compatibility: Designed specifically for Brivis heating systems.
Safety Features: Includes built-in safety mechanisms to prevent overheating and other potential hazards.
Reliability: Genuine Brivis part, ensuring compatibility and performance.
Used in Brivis ducted gas heaters to manage the overall operation and safety of the system.
Turn Off Power and Gas Supply: Ensure the heater is turned off and disconnected from the power supply. Shut off the gas supply to the unit.
Locate the Old Control Interface: Identify the existing electronic control interface in the heater assembly.
Disconnect Wiring: Carefully disconnect the wires connected to the old control interface, noting their positions for reconnection.
Remove the Old Interface: Unscrew or unclip the old control interface from its mounting position.
Install the New Control Interface: Position the new Electronic Control Interface 509 (17529) in place and secure it.
Reconnect Wiring: Attach the wires to the new control interface according to the notes taken during disconnection.
Restore Power and Gas Supply: Turn the gas supply and power back on.
Test the System: Turn on the heater and ensure the new control interface is functioning correctly.
Interface Failure: If the control interface fails, the heater may not ignite or operate properly.
Error Codes: The interface may display error codes indicating specific issues with the heater's operation.
Electrical Issues: Faulty wiring or incorrect voltage can prevent the control interface from operating properly.
Regularly inspect the control interface and wiring for signs of wear or damage.
Ensure the interface is properly ventilated to prevent overheating.
Replace the control interface if it shows signs of failure or reduced performance.
Always follow the manufacturer's instructions and safety guidelines when working with gas appliances.